A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All.....
7.5CVSS
7.2AI Score
0.0005EPSS
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMA...
10CVSS
9.4AI Score
0.002EPSS
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMA...
8.4CVSS
9.1AI Score
0.0005EPSS
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (All versions < V7.2), RUGGEDCOM RM1224 LTE(4G) NAM (All versions < V7.2), SCALANCE M804PB (All versions < V7.2), SCALANCE M812-1 ADSL-Router (Annex A) (All versions < V7.2), SCALANCE M812-1 ADSL-Router (Annex B) (All ve...
7.6CVSS
7.6AI Score
0.0004EPSS
A vulnerability has been identified in SIMATIC CP 1543-1 (incl. SIPLUS variants) (All versions < V3.0), SIMATIC CP 1545-1 (All versions < V1.1). An attacker with access to the subnet of the affected device could retrieve sensitive information stored in...
6.5CVSS
6AI Score
0.001EPSS
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI....
6.5CVSS
6AI Score
0.001EPSS
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not...
6.5CVSS
6.2AI Score